Influenza a+B Antigen Rapid Test Lateral Flow Test Kit

Customization: Available
Type: IVD Reagent
Contents: Rapid Test+Swab+Extraction Tube with Buffer

Products Details

  • Overview
  • Product Description
  • Production Operation
  • Company Profile
Overview

Basic Info.

Model NO.
DWR-80IFAB
Test Type
Qualitative Test
Test Parameter
Influenza a and B Virus
Sample
Nasal Swab
Result Time
15 Mins
Transport Package
625tests/Carton
Specification
25tests/box
Trademark
Dewei
Origin
China
HS Code
3822190090
Production Capacity
500, 000 Tests/Week

Product Description

Influenza A+B Antigen Rapid Test
 

Product Description

Influenza is a contagious respiratory disease caused by influenza viruses. It can cause mild to severe diseases. The severe consequences of influenza infection can lead to hospitalization or death. Some people, such as the elderly, young children, and people with certain health conditions, are prone to severe flu complications. There are two main types of influenza viruses: type A and type B. The influenza A and B (human influenza viruses) that are usually spread among people are the cause of seasonal influenza epidemics every year.

TEST PURPOSE
This product is used for in vitro qualitative detection of influenza A and influenza B virus protein antigens in human swab test samples. The InfluenzaA+B antigen combined rapid test kit is designed to detect and identify influenza A and influenza B virus nucleoprotein antigens. Antigens can generally be detected in nasopharyngeal specimens during the acute infection stage.

TEST METHOD
The rapid test of influenza A+B is a lateral flow chromatography detection method based on the principle of double antibody sandwich technology. The anti-influenza A and influenza B monoclonal antibodies combined with colloidal gold gold particles are used as the label, and gold is sprayed on the binding pad. During the test, the antigen and labeled antibody complexes are formed and migrated on the membrane by capillary action. If the specimen contains influenza A antigen, the complex will be captured by the pre-coated influenza A monoclonal antibody, forming a visible colored line in area A of the result window. If the specimen contains influenza B antigen, the complex will be captured by the precoated influenza B monoclonal antibody, forming a visible color line in the B area of the result window. The control line (C) is used for process control and should always appear if the test process is performed properly.

 

Product Name Influenza A+B Antigen Test Kit
Brand Dewei
Components Reagent cassette (the test kit includes the flu A+B test strip); Swab; Extraction tube with buffer; Leaflet
Usage In-vitro Qualitative Detection
Shelf Life 18 months
Manufacturer Dewei Medical Equipment Co., Ltd
Origin Foshan City, China

TEST IMAGE
Influenza a+B Antigen Rapid Test Lateral Flow Test Kit
Production Operation

SAMPLE REQUIREMENT
Specimens obtained early in the onset of symptoms will contain the highest virus titer;
Specimens obtained 5 days after the onset of symptoms are more likely to produce Positive results; Insufficient specimen collection, improper specimen handling and/or transportation may produce false negative results;
Do not return the nasal swab to the original swab packaging;
Freshly collected specimens should be processed as soon as possible, but no later than 1 hour after specimen collection;
The collected specimens can be stored at 2-8°C for no more than 24 hours;
Store at -70ºC for a long time, but avoid repeated freeze-thaw cycles; Improper sample handling, storage and transportation methods may produce false negative results.

OPERATION
SAMPLE COLLECTION:
This product can be equipped with disposable sampling swabs, sampling is as follows: Nasal Sampling: Gently insert the swab head into the nasal cavity and scrape the cavity wall. Immerse the swab head into sample solution and discard the tail of swab.
DETECTION:
1. Insert the tip onto tube membrane, take out the tip after membrane's puncture.
2. Collect the swab sample according to above instruction.
3. Roll the swab at least 6 times while pressing the head against the bottom and side of the extraction tube.
  Leave the swab into the extraction tube for 1 minute.
  Squeeze the tube by fingers from outside of the tube to immerse the swab.
  Remove the swab. The extracted solution will be used as test sample.
4. Put the tip onto the tube, and take out its cap.
5. Add 2 drops of the mixed sample to each sample wells of the cassette and read the results in 15 minutes.
Influenza a+B Antigen Rapid Test Lateral Flow Test Kit

Company Profile
Dewei Medical Equipment Co., Ltd. is a high-tech enterprise specialized in developing and marketing of Medical Consmuables like Colloidal Gold Rapid Test Kits, Clinical Laboratory analyzer and reagents, Hematology Analyzer and Reagents, Washing Solutions, Urine Sediment Reagents and DNA/RNA Preservation Kits.

Dewei products are widely used in hospital clinics, disease control centers, blood banks, veterinary clinics, scientific research center and college laboratories.
Influenza a+B Antigen Rapid Test Lateral Flow Test Kit


R&D TEAM

Influenza a+B Antigen Rapid Test Lateral Flow Test Kit
Influenza a+B Antigen Rapid Test Lateral Flow Test Kit


PRODUCTION LINE

Influenza a+B Antigen Rapid Test Lateral Flow Test Kit
Influenza a+B Antigen Rapid Test Lateral Flow Test Kit


CERTIFICATES

Influenza a+B Antigen Rapid Test Lateral Flow Test Kit
Influenza a+B Antigen Rapid Test Lateral Flow Test Kit


EXHIBITIONS

Influenza a+B Antigen Rapid Test Lateral Flow Test Kit
Influenza a+B Antigen Rapid Test Lateral Flow Test Kit


PACKAGE & TRANSPORTATION

Influenza a+B Antigen Rapid Test Lateral Flow Test Kit
Influenza a+B Antigen Rapid Test Lateral Flow Test Kit

 

 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours