Overview

Basic Info.

Model NO.
VCO-DS22
Result Time
Within 5 Mins
Principle
Immunochromatography
Shelf Life
24 Months
Certificate
CE
Transport Package
25tests/Box
Specification
1000tests/Carton
Trademark
Dewei
Origin
China

Product Description

 

Intended Use

The Vibrio cholerae Rapid Test is a rapid visual immunoassay for the qualitative, presumptive detection of Vibrio cholerae O1 and/or O139 in human fecal specimens. This kit is intended for use as an aid in the diagnosis of Vibrio cholerae O1 and/or O139 infection.


The Vibrio cholerae O1/O139 Antigen Rapid Test detects Vibrio cholerae O1/O139 through visual interpretation of color development on the internal strip. The test contain two strip in cassette, in each strip, anti- Vibrio cholerae O1/O139 antibodies are immobilized on the test region of the membrane. During testing, the specimen reacts with anti- Vibrio cholerae O1/O139 antibodies conjugated to colored particles and precoated onto the conjugate pad of the test. The mixture then migrates through the membrane by capillary action and interacts with reagents on the membrane. If there is sufficient Vibrio cholerae O1/O139 in the specimen, a colored band will form at the test region of the membrane. The presence of this colored band indicates a positive result, while its absence indicates a negative result. The appearance of a colored band at the control region serves as a procedural control, indicating that the proper volume of specimen has been added and membrane wicking has occurred.
 
Manufacturer Dewei Medical Equipment Co., Ltd 
Product Categories IVD Test
Principle Rapid Colloidal Gold Immunochromatography
Detection Qualitative
Storage 2~30 º C
Component Rapid Test
Package 25T/box, 50T/Box, 100T/Box
Trademark Dewei
Origin China

 

Storage and Stability


The kit should be stored at 2-30°C until the expiry date printed on the sealed pouch.
The test must remain in the sealed pouch until use.
Keep away from direct sunlight, moisture and heat.
Do not freeze.
Care should be taken to protect the components of the kit from contamination. Do not use if there is evidence of microbial contamination or precipitation. Biological contamination of dispensing equipment, containers or reagents can lead to false results. 

 

Operation


Bring tests, specimens, buffer and/or controls to room temperature (15-30°C) before use.
1. Specimen collection and pre-treatment:
Use the specimens collection container provided in the kit for specimens collection. Follow the operation procedure written on it for instructions. Other clean dry containers could also be used for the same purpose. Best results will be obtained if the assay is performed within 6 hours after collection.
For solid specimens: Unscrew and remove the dilution tube applicator. Be careful not to spill or spatter solution from the tube. Collect specimens by inserting the applicator stick into at least 4 different sites of the feces to collect approximately 50 mg of feces (equivalent to 1/4 of a pea).
For liquid specimens: Hold the pipette vertically, aspirate fecal specimens, and then transfer 2 drops (approximately 50 µL) into the specimen collection tube containing the extraction buffer.
Place the applicator back into the tube and screw the cap tightly. Be careful not to break the tip of the dilution tube.
Shake the specimen collection tube vigorously to mix the specimen and the extraction buffer. Specimens prepared in the specimen collection tube may be stored for 6 months at -20°C if not tested within 1 hour after preparation.
2. Testing
Remove the test from its sealed pouch, and place it on a clean, level surface. Label the test with patient or control identification. To obtain a best result, the assay should be performed within one hour.
Using a piece of tissue paper, break the tip of the dilution tube. Hold the tube vertically and dispense 2~3 drops of solution into the specimen well (S) of the test cassette.
Avoid trapping air bubbles in the specimen well (S), and do not drop any solution in observation window.
As the test begins to work, you will see color move across the membrane.
3. Wait for the colored band(s) to appear. The result should be read at 10 minutes. Do not interpret the result after 20 minutes.
Note: If the specimen does not migrate (presence of particles), centrifuge the extracted specimens contained in the extraction buffer vial. Collect 80 µL of supernatant, dispense into the specimen well (S) of a new test cassette and start afresh following the instructions mentioned above.
Dewei Medical Rapid Test Cholera O1/O139 Combo Rapid Test
 
INTERPRETATION OF RESULTS
Preliminary positive (+): Only one colored band appears, in the control region (C). No colored band appears in the test region (T)
Negative (-): Two colored bands appear on the membrane. One band appears in the control region (C) and another band appears in the test region (T).
Invalid:Control band fails to appear. Results from any test which has not produced a control band at the specified read time must be discarded. Please review the procedure and repeat it with a new test.
Dewei Medical Rapid Test Cholera O1/O139 Combo Rapid Test

 

 

Detailed Photos

 

Dewei Medical Rapid Test Cholera O1/O139 Combo Rapid Test
Dewei Medical Rapid Test Cholera O1/O139 Combo Rapid Test

 

Company Profile

 

About Us

Dewei Medical Rapid Test Cholera O1/O139 Combo Rapid TestDEWEI Medical Equipment Co., Ltd is a leading and professional manufacturer of IVD products, it is a high-tech enterprise specialized in developing, manufacturing, and marketing IVD products.
DEWEI products are widely used in hospital clinics, disease control centers, blood banks, veterinary clinics, scientific research centers, and college laboratories. Quality is the primary concern, DEWEI team is strict on quality control systems thus our products have CE, ISO, CFDA, and other international standards certificates.
The view of DEWEI is to be the most professional and respected enterprise in the IVD field, DEWEI will go on to provide the best service to you with outstanding R&D and cost-effective products.

 

R&D team
15% of the annual sales amount is devoted to the R&D department.
With a professional R&D team, Dewei is continuously making new achievements in innovation, gaining a number of national invention patents and professional technical awards. Meanwhile, Dewei focuses on the improvement of technology to guarantee product quality and pursue product performance.
Dewei Medical Rapid Test Cholera O1/O139 Combo Rapid Test


Certificate
Dewei Medical Rapid Test Cholera O1/O139 Combo Rapid Test

Production Workshop

Dewei Medical Rapid Test Cholera O1/O139 Combo Rapid Test

Exhibition
Dewei Medical Rapid Test Cholera O1/O139 Combo Rapid Test
Dewei Medical Rapid Test Cholera O1/O139 Combo Rapid Test
 

Transportation
Dewei Medical Rapid Test Cholera O1/O139 Combo Rapid Test

FAQ

1, Are you a manufacturer?
Yes, we are a manufacturer based in Foshan City, Guangdong province. We have different production lines, more than 5000 square meter facility.

2, Can you put our logo or text on the products or packages?
Yes, we can provide OEM goods.

3, Could you provide free samples for our testing before we place an order?
Sure, we'd like to offer free samples for you, but the freight cost should be paid by the buyer.

4, How to make payment?
T/T, D/P, L/C, Paypal, Western Union and Made in China are both acceptable.

5, Which seaport ad airport are the nearest to your factory?
The near seaport is Guangzhou Nansha seaport & Shenzhen Shekou seaport. And Guangzhou, Shenzhen, & Hongkong Airports are both convenient.

6,  What is your best delivery time?
Depend on your order quantities. 3-20 working days after payment is received.

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours